{"ExteriorFloor_U_value":{"Applied to class":"ExteriorFloor","Default":1.0,"Full Name":"Heat Transfer Coefficient of the exterior floors","Maximum":4.4,"Minimum":0.0,"Name in dimosim":"U_value","Name in geoJSON":"ExteriorFloor_U_value","Type":"Numerical data","Unit":"W/m2.K"},"ExteriorFloor_inertia":{"Applied to class":"ExteriorFloor","Default":"mid","Full Name":"Inertia of the floors","Name in dimosim":"inertia","Name in geoJSON":"ExteriorFloor_inertia","Possible Values":["high","low","mid"],"Type":"Categorical data"},"ExteriorFloor_insulation":{"Applied to class":"ExteriorFloor","Default":"indoor","Full Name":"Position of the insulation of the floors","Name in dimosim":"insulation","Name in geoJSON":"ExteriorFloor_insulation","Possible Values":["indoor","outdoor"],"Type":"Categorical data"},"ExteriorRoof_U_value":{"Applied to class":"ExteriorRoof","Default":1.0,"Full Name":"Heat Transfer Coefficient of the exterior roofs","Maximum":4.4,"Minimum":0.0,"Name in dimosim":"U_value","Name in geoJSON":"ExteriorRoof_U_value","Type":"Numerical data","Unit":"W/m2.K"},"ExteriorRoof_inertia":{"Applied to class":"ExteriorRoof","Default":"mid","Full Name":"Inertia of the roofs","Name in dimosim":"inertia","Name in geoJSON":"ExteriorRoof_inertia","Possible Values":["high","low","mid"],"Type":"Categorical data"},"ExteriorRoof_insulation":{"Applied to class":"ExteriorRoof","Default":"indoor","Full Name":"Position of the insulation of the roofs","Name in dimosim":"insulation","Name in geoJSON":"ExteriorRoof_insulation","Possible Values":["indoor","outdoor"],"Type":"Categorical data"},"ExteriorRoof_window_share":{"Applied to class":"ExteriorRoof","Default":0.0,"Full Name":"Share of surface occupied by windows in the roofs","Maximum":0.99,"Minimum":0.0,"Name in dimosim":"window_share","Name in geoJSON":"ExteriorRoof_window_share","Type":"Numerical data","Unit":"no unit"},"ExteriorRoof_window_type":{"Applied to class":"ExteriorRoof","Default":"double_glazing","Full Name":"Type of windows of the roofs","Name in dimosim":"window_type","Name in geoJSON":"ExteriorRoof_window_type","Possible Values":"None or str","Type":"Categorical data"},"ExteriorWall_U_value":{"Applied to class":"ExteriorWall","Default":1.0,"Full Name":"Heat Transfer Coefficient of the exterior walls","Maximum":4.4,"Minimum":0.0,"Name in dimosim":"U_value","Name in geoJSON":"ExteriorWall_U_value","Type":"Numerical data","Unit":"W/m2.K"},"ExteriorWall_inertia":{"Applied to class":"ExteriorWall","Default":"mid","Full Name":"Inertia of the walls","Name in dimosim":"inertia","Name in geoJSON":"ExteriorWall_inertia","Possible Values":["high","low","mid"],"Type":"Categorical data"},"ExteriorWall_insulation":{"Applied to class":"ExteriorWall","Default":"indoor","Full Name":"Position of the insulation of the walls","Name in dimosim":"insulation","Name in geoJSON":"ExteriorWall_insulation","Possible Values":["indoor","outdoor"],"Type":"Categorical data"},"ExteriorWall_window_share":{"Applied to class":"ExteriorWall","Default":0.15,"Full Name":"Share of surface occupied by windows in the walls","Maximum":0.99,"Minimum":0.0,"Name in dimosim":"window_share","Name in geoJSON":"ExteriorWall_window_share","Type":"Numerical data","Unit":"no unit"},"ExteriorWall_window_type":{"Applied to class":"ExteriorWall","Default":"double_glazing","Full Name":"Type of windows of the walls","Name in dimosim":"window_type","Name in geoJSON":"ExteriorWall_window_type","Possible Values":"None or str","Type":"Categorical data"},"altitude":{"Applied to class":"ThermalZone","Default":0.0,"Full Name":"Altitude of the thermal zone","Maximum":null,"Minimum":0.0,"Name in dimosim":"altitude","Name in geoJSON":"altitude","Type":"Numerical data","Unit":"meters"},"building_id":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Name of the Building to which the ThermalZone belongs","Name in dimosim":"building_id","Name in geoJSON":"building_id","Possible Values":"None or str","Type":"Categorical data"},"district_linked_0":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Name of the DistrictHydroDistribution to which a BuildingSubstation is linked","Name in dimosim":"district_linked","Name in geoJSON":"district_linked_0","Possible Values":"str","Type":"Categorical data","missing value":null},"district_linked_1":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Name of the DistrictHydroDistribution to which a BuildingSubstation is linked","Name in dimosim":"district_linked","Name in geoJSON":"district_linked_1","Possible Values":"str","Type":"Categorical data","missing value":null},"district_linked_2":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Name of the DistrictHydroDistribution to which a BuildingSubstation is linked","Name in dimosim":"district_linked","Name in geoJSON":"district_linked_2","Possible Values":"str","Type":"Categorical data","missing value":null},"district_linked_3":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Name of the DistrictHydroDistribution to which a BuildingSubstation is linked","Name in dimosim":"district_linked","Name in geoJSON":"district_linked_3","Possible Values":"str","Type":"Categorical data","missing value":null},"floor_count":{"Applied to class":"ThermalZone","Default":1.0,"Full Name":"Number of floors in the thermal zone","Maximum":null,"Minimum":0.0,"Name in dimosim":"floor_count","Name in geoJSON":"floor_count","Type":"Numerical data","Unit":"meters"},"height":{"Applied to class":"ThermalZone","Default":3.0,"Full Name":"Height of the thermal zone","Maximum":null,"Minimum":0.0,"Name in dimosim":"height","Name in geoJSON":"height","Type":"Numerical data","Unit":"meters"},"infiltration_rate":{"Applied to class":"ThermalZone","Default":0.0,"Full Name":"Air change rate due","Maximum":10.0,"Minimum":0.0,"Name in dimosim":"infiltration_rate","Name in geoJSON":"infiltration_rate","Type":"Numerical data","Unit":"vol/h"},"name":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Name of the Thermal zone","Name in dimosim":"name","Name in geoJSON":"name","Possible Values":"None or str","Type":"Categorical data"},"systems_0":{"Applied to class":"ThermalZone","Default":"ZoneElectricHeaterElectricityHeating","Full Name":"Systems of the thermal zone","Name in dimosim":"systems","Name in geoJSON":"systems_0","Possible Values":["DistrictDistributedwaterstorage","DistrictBoilerBiomassHeatingDHWCondensing","DistrictCustomGenerator","DistrictWaterWaterHeatPumpDryCoolingTowerCooling","DistrictWaterWaterHeatPumpDetailedDryTowerHeatingDHW","DistrictTemperedSourceUserPowerHeatingCooling","DistrictGeothermal","DistrictMultiGeneratorTemperedSourcePower","DistrictMultiGeneratorTemperedSource","DistrictWaterWaterHeatPumpHumidCoolingTowerCooling","DistrictWaterWaterHeatPumpDryTowerHeatingCooling","DistrictTemperedSourceUserHxHeatingCooling","DistrictMultiGeneratorTemperedSourceHx","DistrictWaterWaterHeatPumpDryTowerHeatingDHW","DistrictThermoRefrigeratingHeatPumpSourceUserHeatingCooling","DistrictMultigeneratorCooling","DistrictMultigeneratorHeating","DistrictBoilerGasHeatingDHWCondensing","DistrictWaterWaterHeatPumpSourceUserHeatingCooling","ZoneBoilerDetailedOilHeatingCondensing","ZoneCoolingDemand","ZoneWaterWaterHeatPumpDetailedGasHeatingDryTower","ZoneBoilerDetailedBiomassHeatingStandard","ZoneWaterWaterHeatPumpElectricityHeatingDHWSourceUser","ZoneAirWaterHeatPumpDetailedElectricityCooling","ZoneBoilerGasHeatingCondensing","ZoneBoilerDetailedOilHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingSourceUser","ZoneBoilerBiomassDHWCondensing","ZoneBoilerDetailedGasHeatingCondensing","ZoneCombinedHeatPowerDetailedGasHeatingDHWStirling","ZoneBoilerBiomassDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingStirling","ZoneBoilerDetailedBiomassHeatingCondensing","ZoneAirWaterHeatPumpDetailedGasCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","ZoneGasHeaterDetailedGasHeating","ZoneWaterWaterHeatPumpDetailedGasCoolingHumidTower","ZoneDoubleFlowVentilationWithoutRecovery","ZoneBoilerDetailedGasHeatingStandard","ZoneCombinedHeatPowerDetailedGasHeatingDHWTurbine","ZoneBoilerDetailedGasDHWCondensing","ZoneBoilerDetailedBiomassHeatingDHWCondensing","ZoneAirWaterHeatPumpElectricityCooling","ZoneHeatingDemand","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","ZoneBoilerOilHeating","ZoneAirWaterHeatPumpElectricityHeatingCooling","ZoneAirWaterHeatPumpDetailedElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","ZoneBoilerDetailedBiomassHeatingDHWStandard","ZoneAirWaterHeatPumpGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingTurbine","ZoneAirWaterHeatPumpDetailedGasHeatingDHW","ZoneBoilerDetailedOilHeatingDHWCondensing","ZoneAirAirHeatPumpElectricityHeating","ZoneInstantaneousBoilerDetailedGasDHWCondensing","ZoneAirWaterHeatPumpDetailedGasHeating","ZoneElectricHeaterWaterElectricityDHW","ZoneAirWaterHeatPumpGasDHW","ZoneInletOutletIntakeFlowVentilation","ZoneCoolingDehumidifyingDemand","ZoneCombinedHeatPowerDetailedGasHeatingTurbine","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityCoolingSourceUser","ZoneWaterWaterHeatPumpGasHeatingDryTower","ZoneCombinedHeatPowerGasHeatingDHWFuelCell","ZoneWaterWaterHeatPumpElectricityCoolingHumidTower","ZoneDoubleFlowVentilationWithRecovery","ZoneWaterWaterHeatPumpGasCoolingDryTower","ZoneAirAirHeatPumpDetailedElectricityHeatingCooling","ZoneAirAirHeatPumpDetailedElectricityHeating","ZoneWaterWaterHeatPumpDetailedElectricityCoolingDryTower","ZoneAirWaterHeatPumpElectricityHeating","ZoneWaterWaterHeatPumpElectricityCoolingDryTower","ZoneAirAirHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCoolingDehumidifying","ZoneAirWaterHeatPumpDetailedGasDHW","ZoneBoilerGasDHWStandard","ZoneInstantaneousBoilerDetailedGasDHWStandard","ZoneWaterWaterHeatPumpDetailedGasCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityHeatingCooling","ZoneSingleFlowVentilation","ZoneDHWDemand","ZoneCombinedHeatPowerGasHeatingFuelCell","ZoneCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","ZoneInstantaneousBoilerElectricityHeatingStandard","ZoneBoilerOilHeatingStandard","ZoneWaterWaterHeatPumpGasHeatingCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityDHW","ZoneAirAirHeatPumpDetailedElectricityCooling","ZoneWaterWaterHeatPumpGasHeatingSourceUser","ZoneAirWaterHeatPumpGasCooling","ZoneAirWaterHeatPumpElectricityDHW","ZoneVentHeatingElementVentilation","ZoneBoilerBiomassHeatingStandard","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCooling","ZoneBoilerGasHeatingStandard","ZoneBoilerOilDHWCondensing","ZoneElectricHeaterWaterElectricityDHWSolar","ZoneBoilerDetailedGasHeatingDHWCondensing","ZoneWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","ZoneBoilerDetailedOilHeatingStandard","ZoneAirAirHeatPumpElectricityHeatingCooling","ZoneElectricHeaterElectricityHeating","ZoneAirWaterHeatPumpGasHeating","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCooling","ZoneAirHandlingUnitReturnAirBoilerDetailedStandardGasHeating","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCooling","ZoneInstantaneousBoilerGasDHWStandard","ZoneBoilerBiomassHeating","ZoneBoilerGasDHWCondensing","ZoneBoilerOilHeatingCondensing","ZoneInstantaneousBoilerElectricityDHWStandard","ZoneAirAirHeatPumpDetailedElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpDetailedElectricityCoolingDehumidifying","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeating","ZoneCombinedHeatPowerGasHeatingInternalCombustionEngine","ZoneBoilerDetailedGasHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingCoolingDryTower","ZoneHeatRecoveryVentilation","ZoneBoilerOilDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","ZoneWaterWaterHeatPumpElectricityHeatingDryTower","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDryTower","ZoneBoilerDetailedGasDHWStandard","ZoneAirWaterHeatPumpDetailedElectricityHeating","ZoneAirWaterHeatPumpElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","ZoneWaterWaterHeatPumpGasHeatingDHWSourceUser","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeating","ZoneAirWaterHeatPumpDetailedGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingStirling","ZoneWaterWaterHeatPumpGasCoolingHumidTower","ZoneBoilerBiomassHeatingCondensing","ZoneAirAirHeatPumpElectricityCooling","BuildingWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","BuildingSubstationHxHeatingMT","BuildingWaterWaterHeatPumpElectricityHeatingDHWSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","BuildingBoilerDetailedGasHeatingCondensing","BuildingBoilerBiomassHeatingCondensing","BuildingAirWaterHeatPumpElectricityDHW","BuildingBoilerDetailedGasHeatingDHWStandard","BuildingAirWaterHeatPumpDetailedElectricityHeatingCooling","BuildingWaterWaterHeatPumpElectricityHeatingSourceUser","BuildingBoilerDetailedBiomassHeatingDHWStandard","BuildingBoilerOilHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingDryTower","BuildingBoilerOilHeatingCondensing","BuildingBoilerDetailedGasHeatingDHWCondensing","BuildingBoilerDetailedBiomassHeatingCondensing","BuildingSubstationHeatPumpDetailedCooling","BuildingAirWaterHeatPumpGasHeatingCooling","BuildingBoilerDetailedOilHeatingDHWStandard","BuildingSubstationHxCooling","BuildingSubstationThermoFrigoPumpHeatingDHW","BuildingCombinedHeatPowerDetailedGasHeatingTurbine","BuildingCombinedHeatPowerGasHeatingDHWStirling","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCoolingDHW","BuildingCombinedHeatPowerDetailedGasHeatingDHWStirling","BuildingBoilerDetailedOilHeatingCondensing","BuildingSubstationHxDHW","BuildingBoilerDetailedGasHeatingStandard","BuildingSubstationHeatPumpHeating","BuildingAirWaterHeatPumpDetailedElectricityHeatingDHW","BuildingWaterWaterHeatPumpDetailedElectricityCoolingDryTower","BuildingBoilerDetailedBiomassHeatingStandard","BuildingBoilerGasHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","BuildingSubstationSimpleThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingDHWHT","BuildingWaterWaterHeatPumpDetailedGasCoolingHumidTower","BuildingBoilerGasHeatingDHWCondensing","BuildingAirWaterHeatPumpGasHeatingDHW","BuildingCustomHeatPumpElectricityDHW","BuildingAirWaterHeatPumpDetailedElectricityCooling","BuildingCombinedHeatPowerGasHeatingDHWInternalCombustionEngine","BuildingSubstationHeatPumpDetailedHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","BuildingSubstationHeatPumpHeatingDHW","BuildingAirWaterHeatPumpDetailedGasHeating","BuildingSubstationHeatPumpDHW","BuildingWaterWaterHeatPumpElectricityHeatingCoolingDryTower","BuildingSubstationHxCoolingLT","BuildingSubstationSimpleThermoFrigoPumpHeatingCoolingDHW","BuildingAirWaterHeatPumpDetailedElectricityDHW","BuildingAirWaterHeatPumpGasHeating","BuildingCombinedHeatPowerGasHeatingTurbine","BuildingWaterWaterHeatPumpGasHeatingDHWSourceUser","BuildingSubstationHeatPumpCooling","BuildingAirWaterHeatPumpDetailedGasHeatingDHW","BuildingSubstationHxHeatingHT","BuildingCombinedHeatPowerGasHeatingDHWFuelCell","BuildingWaterWaterHeatPumpDetailedGasCoolingDryTower","BuildingBoilerDetailedBiomassHeatingDHWCondensing","BuildingWaterWaterHeatPumpGasCoolingDryTower","BuildingBoilerGasHeatingDHWStandard","BuildingBoilerGasDHWStandard","BuildingWaterWaterHeatPumpGasCoolingHumidTower","BuildingAirWaterHeatPumpElectricityHeatingDHW","BuildingBoilerBiomassHeatingDHWStandard","BuildingBoilerOilHeatingDHWCondensing","BuildingSubstationHxHeatingDHW","BuildingWaterWaterHeatPumpElectricityCoolingSourceUser","BuildingSubstationHxCoolingHT","BuildingCombinedHeatPowerGasHeatingFuelCell","BuildingSubstationHxHeating","BuildingCombinedHeatPowerDetailedGasHeatingDHWTurbine","BuildingCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","BuildingBoilerDetailedGasDHWCondensing","BuildingAirWaterHeatPumpElectricityHeatingCooling","BuildingCustomHeatPumpElectricityHeating","BuildingSubstationHeatPumpDetailedDHW","BuildingAirWaterHeatPumpDetailedElectricityHeating","BuildingBoilerDetailedOilHeatingDHWCondensing","BuildingBoilerOilHeatingDHWStandard","BuildingSubstationThermoFrigoPumpCooling","BuildingSubstationHxHeatingCooling","BuildingSubstationHeatPumpDetailedHeating","BuildingSubstationHeatPumpDetailedHeatingDHW","BuildingCustomHeatPumpElectricityHeatingDHW","BuildingBoilerGasHeatingCondensing","BuildingSubstationHeatPumpHeatingCooling","BuildingSubstationThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingLT","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","BuildingWaterWaterHeatPumpElectricityCoolingHumidTower","BuildingSubstationThermoFrigoPumpHeating","BuildingSubstationHxCoolingMT","BuildingCombinedHeatPowerGasHeatingStirling","BuildingWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","BuildingAirWaterHeatPumpDetailedGasCooling","BuildingBoilerDetailedGasDHWStandard","BuildingBoilerBiomassHeatingStandard","BuildingSubstationHxHeatingDHWMT","BuildingSubstationThermoFrigoPumpHeatingCoolingDHW","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCooling","BuildingBoilerBiomassHeatingDHWCondensing","BuildingAirWaterHeatPumpElectricityHeating","BuildingAirWaterHeatPumpDetailedGasHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingStirling","BuildingCombinedHeatPowerGasHeatingInternalCombustionEngine","BuildingWaterWaterHeatPumpElectricityCoolingDryTower","BuildingBoilerDetailedOilHeatingStandard","BuildingAirWaterHeatPumpDetailedGasDHW","BuildingCombinedHeatPowerGasHeatingDHWTurbine","BuildingWaterWaterHeatPumpGasHeatingDryTower","BuildingWaterWaterHeatPumpGasHeatingCoolingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDryTower"],"Type":"Categorical data","missing value":null},"systems_1":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Systems of the thermal zone","Name in dimosim":"systems","Name in geoJSON":"systems_1","Possible Values":["DistrictDistributedwaterstorage","DistrictBoilerBiomassHeatingDHWCondensing","DistrictCustomGenerator","DistrictWaterWaterHeatPumpDryCoolingTowerCooling","DistrictWaterWaterHeatPumpDetailedDryTowerHeatingDHW","DistrictTemperedSourceUserPowerHeatingCooling","DistrictGeothermal","DistrictMultiGeneratorTemperedSourcePower","DistrictMultiGeneratorTemperedSource","DistrictWaterWaterHeatPumpHumidCoolingTowerCooling","DistrictWaterWaterHeatPumpDryTowerHeatingCooling","DistrictTemperedSourceUserHxHeatingCooling","DistrictMultiGeneratorTemperedSourceHx","DistrictWaterWaterHeatPumpDryTowerHeatingDHW","DistrictThermoRefrigeratingHeatPumpSourceUserHeatingCooling","DistrictMultigeneratorCooling","DistrictMultigeneratorHeating","DistrictBoilerGasHeatingDHWCondensing","DistrictWaterWaterHeatPumpSourceUserHeatingCooling","ZoneBoilerDetailedOilHeatingCondensing","ZoneCoolingDemand","ZoneWaterWaterHeatPumpDetailedGasHeatingDryTower","ZoneBoilerDetailedBiomassHeatingStandard","ZoneWaterWaterHeatPumpElectricityHeatingDHWSourceUser","ZoneAirWaterHeatPumpDetailedElectricityCooling","ZoneBoilerGasHeatingCondensing","ZoneBoilerDetailedOilHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingSourceUser","ZoneBoilerBiomassDHWCondensing","ZoneBoilerDetailedGasHeatingCondensing","ZoneCombinedHeatPowerDetailedGasHeatingDHWStirling","ZoneBoilerBiomassDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingStirling","ZoneBoilerDetailedBiomassHeatingCondensing","ZoneAirWaterHeatPumpDetailedGasCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","ZoneGasHeaterDetailedGasHeating","ZoneWaterWaterHeatPumpDetailedGasCoolingHumidTower","ZoneDoubleFlowVentilationWithoutRecovery","ZoneBoilerDetailedGasHeatingStandard","ZoneCombinedHeatPowerDetailedGasHeatingDHWTurbine","ZoneBoilerDetailedGasDHWCondensing","ZoneBoilerDetailedBiomassHeatingDHWCondensing","ZoneAirWaterHeatPumpElectricityCooling","ZoneHeatingDemand","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","ZoneBoilerOilHeating","ZoneAirWaterHeatPumpElectricityHeatingCooling","ZoneAirWaterHeatPumpDetailedElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","ZoneBoilerDetailedBiomassHeatingDHWStandard","ZoneAirWaterHeatPumpGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingTurbine","ZoneAirWaterHeatPumpDetailedGasHeatingDHW","ZoneBoilerDetailedOilHeatingDHWCondensing","ZoneAirAirHeatPumpElectricityHeating","ZoneInstantaneousBoilerDetailedGasDHWCondensing","ZoneAirWaterHeatPumpDetailedGasHeating","ZoneElectricHeaterWaterElectricityDHW","ZoneAirWaterHeatPumpGasDHW","ZoneInletOutletIntakeFlowVentilation","ZoneCoolingDehumidifyingDemand","ZoneCombinedHeatPowerDetailedGasHeatingTurbine","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityCoolingSourceUser","ZoneWaterWaterHeatPumpGasHeatingDryTower","ZoneCombinedHeatPowerGasHeatingDHWFuelCell","ZoneWaterWaterHeatPumpElectricityCoolingHumidTower","ZoneDoubleFlowVentilationWithRecovery","ZoneWaterWaterHeatPumpGasCoolingDryTower","ZoneAirAirHeatPumpDetailedElectricityHeatingCooling","ZoneAirAirHeatPumpDetailedElectricityHeating","ZoneWaterWaterHeatPumpDetailedElectricityCoolingDryTower","ZoneAirWaterHeatPumpElectricityHeating","ZoneWaterWaterHeatPumpElectricityCoolingDryTower","ZoneAirAirHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCoolingDehumidifying","ZoneAirWaterHeatPumpDetailedGasDHW","ZoneBoilerGasDHWStandard","ZoneInstantaneousBoilerDetailedGasDHWStandard","ZoneWaterWaterHeatPumpDetailedGasCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityHeatingCooling","ZoneSingleFlowVentilation","ZoneDHWDemand","ZoneCombinedHeatPowerGasHeatingFuelCell","ZoneCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","ZoneInstantaneousBoilerElectricityHeatingStandard","ZoneBoilerOilHeatingStandard","ZoneWaterWaterHeatPumpGasHeatingCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityDHW","ZoneAirAirHeatPumpDetailedElectricityCooling","ZoneWaterWaterHeatPumpGasHeatingSourceUser","ZoneAirWaterHeatPumpGasCooling","ZoneAirWaterHeatPumpElectricityDHW","ZoneVentHeatingElementVentilation","ZoneBoilerBiomassHeatingStandard","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCooling","ZoneBoilerGasHeatingStandard","ZoneBoilerOilDHWCondensing","ZoneElectricHeaterWaterElectricityDHWSolar","ZoneBoilerDetailedGasHeatingDHWCondensing","ZoneWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","ZoneBoilerDetailedOilHeatingStandard","ZoneAirAirHeatPumpElectricityHeatingCooling","ZoneElectricHeaterElectricityHeating","ZoneAirWaterHeatPumpGasHeating","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCooling","ZoneAirHandlingUnitReturnAirBoilerDetailedStandardGasHeating","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCooling","ZoneInstantaneousBoilerGasDHWStandard","ZoneBoilerBiomassHeating","ZoneBoilerGasDHWCondensing","ZoneBoilerOilHeatingCondensing","ZoneInstantaneousBoilerElectricityDHWStandard","ZoneAirAirHeatPumpDetailedElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpDetailedElectricityCoolingDehumidifying","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeating","ZoneCombinedHeatPowerGasHeatingInternalCombustionEngine","ZoneBoilerDetailedGasHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingCoolingDryTower","ZoneHeatRecoveryVentilation","ZoneBoilerOilDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","ZoneWaterWaterHeatPumpElectricityHeatingDryTower","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDryTower","ZoneBoilerDetailedGasDHWStandard","ZoneAirWaterHeatPumpDetailedElectricityHeating","ZoneAirWaterHeatPumpElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","ZoneWaterWaterHeatPumpGasHeatingDHWSourceUser","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeating","ZoneAirWaterHeatPumpDetailedGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingStirling","ZoneWaterWaterHeatPumpGasCoolingHumidTower","ZoneBoilerBiomassHeatingCondensing","ZoneAirAirHeatPumpElectricityCooling","BuildingWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","BuildingSubstationHxHeatingMT","BuildingWaterWaterHeatPumpElectricityHeatingDHWSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","BuildingBoilerDetailedGasHeatingCondensing","BuildingBoilerBiomassHeatingCondensing","BuildingAirWaterHeatPumpElectricityDHW","BuildingBoilerDetailedGasHeatingDHWStandard","BuildingAirWaterHeatPumpDetailedElectricityHeatingCooling","BuildingWaterWaterHeatPumpElectricityHeatingSourceUser","BuildingBoilerDetailedBiomassHeatingDHWStandard","BuildingBoilerOilHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingDryTower","BuildingBoilerOilHeatingCondensing","BuildingBoilerDetailedGasHeatingDHWCondensing","BuildingBoilerDetailedBiomassHeatingCondensing","BuildingSubstationHeatPumpDetailedCooling","BuildingAirWaterHeatPumpGasHeatingCooling","BuildingBoilerDetailedOilHeatingDHWStandard","BuildingSubstationHxCooling","BuildingSubstationThermoFrigoPumpHeatingDHW","BuildingCombinedHeatPowerDetailedGasHeatingTurbine","BuildingCombinedHeatPowerGasHeatingDHWStirling","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCoolingDHW","BuildingCombinedHeatPowerDetailedGasHeatingDHWStirling","BuildingBoilerDetailedOilHeatingCondensing","BuildingSubstationHxDHW","BuildingBoilerDetailedGasHeatingStandard","BuildingSubstationHeatPumpHeating","BuildingAirWaterHeatPumpDetailedElectricityHeatingDHW","BuildingWaterWaterHeatPumpDetailedElectricityCoolingDryTower","BuildingBoilerDetailedBiomassHeatingStandard","BuildingBoilerGasHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","BuildingSubstationSimpleThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingDHWHT","BuildingWaterWaterHeatPumpDetailedGasCoolingHumidTower","BuildingBoilerGasHeatingDHWCondensing","BuildingAirWaterHeatPumpGasHeatingDHW","BuildingCustomHeatPumpElectricityDHW","BuildingAirWaterHeatPumpDetailedElectricityCooling","BuildingCombinedHeatPowerGasHeatingDHWInternalCombustionEngine","BuildingSubstationHeatPumpDetailedHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","BuildingSubstationHeatPumpHeatingDHW","BuildingAirWaterHeatPumpDetailedGasHeating","BuildingSubstationHeatPumpDHW","BuildingWaterWaterHeatPumpElectricityHeatingCoolingDryTower","BuildingSubstationHxCoolingLT","BuildingSubstationSimpleThermoFrigoPumpHeatingCoolingDHW","BuildingAirWaterHeatPumpDetailedElectricityDHW","BuildingAirWaterHeatPumpGasHeating","BuildingCombinedHeatPowerGasHeatingTurbine","BuildingWaterWaterHeatPumpGasHeatingDHWSourceUser","BuildingSubstationHeatPumpCooling","BuildingAirWaterHeatPumpDetailedGasHeatingDHW","BuildingSubstationHxHeatingHT","BuildingCombinedHeatPowerGasHeatingDHWFuelCell","BuildingWaterWaterHeatPumpDetailedGasCoolingDryTower","BuildingBoilerDetailedBiomassHeatingDHWCondensing","BuildingWaterWaterHeatPumpGasCoolingDryTower","BuildingBoilerGasHeatingDHWStandard","BuildingBoilerGasDHWStandard","BuildingWaterWaterHeatPumpGasCoolingHumidTower","BuildingAirWaterHeatPumpElectricityHeatingDHW","BuildingBoilerBiomassHeatingDHWStandard","BuildingBoilerOilHeatingDHWCondensing","BuildingSubstationHxHeatingDHW","BuildingWaterWaterHeatPumpElectricityCoolingSourceUser","BuildingSubstationHxCoolingHT","BuildingCombinedHeatPowerGasHeatingFuelCell","BuildingSubstationHxHeating","BuildingCombinedHeatPowerDetailedGasHeatingDHWTurbine","BuildingCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","BuildingBoilerDetailedGasDHWCondensing","BuildingAirWaterHeatPumpElectricityHeatingCooling","BuildingCustomHeatPumpElectricityHeating","BuildingSubstationHeatPumpDetailedDHW","BuildingAirWaterHeatPumpDetailedElectricityHeating","BuildingBoilerDetailedOilHeatingDHWCondensing","BuildingBoilerOilHeatingDHWStandard","BuildingSubstationThermoFrigoPumpCooling","BuildingSubstationHxHeatingCooling","BuildingSubstationHeatPumpDetailedHeating","BuildingSubstationHeatPumpDetailedHeatingDHW","BuildingCustomHeatPumpElectricityHeatingDHW","BuildingBoilerGasHeatingCondensing","BuildingSubstationHeatPumpHeatingCooling","BuildingSubstationThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingLT","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","BuildingWaterWaterHeatPumpElectricityCoolingHumidTower","BuildingSubstationThermoFrigoPumpHeating","BuildingSubstationHxCoolingMT","BuildingCombinedHeatPowerGasHeatingStirling","BuildingWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","BuildingAirWaterHeatPumpDetailedGasCooling","BuildingBoilerDetailedGasDHWStandard","BuildingBoilerBiomassHeatingStandard","BuildingSubstationHxHeatingDHWMT","BuildingSubstationThermoFrigoPumpHeatingCoolingDHW","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCooling","BuildingBoilerBiomassHeatingDHWCondensing","BuildingAirWaterHeatPumpElectricityHeating","BuildingAirWaterHeatPumpDetailedGasHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingStirling","BuildingCombinedHeatPowerGasHeatingInternalCombustionEngine","BuildingWaterWaterHeatPumpElectricityCoolingDryTower","BuildingBoilerDetailedOilHeatingStandard","BuildingAirWaterHeatPumpDetailedGasDHW","BuildingCombinedHeatPowerGasHeatingDHWTurbine","BuildingWaterWaterHeatPumpGasHeatingDryTower","BuildingWaterWaterHeatPumpGasHeatingCoolingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDryTower"],"Type":"Categorical data","missing value":null},"systems_2":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Systems of the thermal zone","Name in dimosim":"systems","Name in geoJSON":"systems_2","Possible Values":["DistrictDistributedwaterstorage","DistrictBoilerBiomassHeatingDHWCondensing","DistrictCustomGenerator","DistrictWaterWaterHeatPumpDryCoolingTowerCooling","DistrictWaterWaterHeatPumpDetailedDryTowerHeatingDHW","DistrictTemperedSourceUserPowerHeatingCooling","DistrictGeothermal","DistrictMultiGeneratorTemperedSourcePower","DistrictMultiGeneratorTemperedSource","DistrictWaterWaterHeatPumpHumidCoolingTowerCooling","DistrictWaterWaterHeatPumpDryTowerHeatingCooling","DistrictTemperedSourceUserHxHeatingCooling","DistrictMultiGeneratorTemperedSourceHx","DistrictWaterWaterHeatPumpDryTowerHeatingDHW","DistrictThermoRefrigeratingHeatPumpSourceUserHeatingCooling","DistrictMultigeneratorCooling","DistrictMultigeneratorHeating","DistrictBoilerGasHeatingDHWCondensing","DistrictWaterWaterHeatPumpSourceUserHeatingCooling","ZoneBoilerDetailedOilHeatingCondensing","ZoneCoolingDemand","ZoneWaterWaterHeatPumpDetailedGasHeatingDryTower","ZoneBoilerDetailedBiomassHeatingStandard","ZoneWaterWaterHeatPumpElectricityHeatingDHWSourceUser","ZoneAirWaterHeatPumpDetailedElectricityCooling","ZoneBoilerGasHeatingCondensing","ZoneBoilerDetailedOilHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingSourceUser","ZoneBoilerBiomassDHWCondensing","ZoneBoilerDetailedGasHeatingCondensing","ZoneCombinedHeatPowerDetailedGasHeatingDHWStirling","ZoneBoilerBiomassDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingStirling","ZoneBoilerDetailedBiomassHeatingCondensing","ZoneAirWaterHeatPumpDetailedGasCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","ZoneGasHeaterDetailedGasHeating","ZoneWaterWaterHeatPumpDetailedGasCoolingHumidTower","ZoneDoubleFlowVentilationWithoutRecovery","ZoneBoilerDetailedGasHeatingStandard","ZoneCombinedHeatPowerDetailedGasHeatingDHWTurbine","ZoneBoilerDetailedGasDHWCondensing","ZoneBoilerDetailedBiomassHeatingDHWCondensing","ZoneAirWaterHeatPumpElectricityCooling","ZoneHeatingDemand","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","ZoneBoilerOilHeating","ZoneAirWaterHeatPumpElectricityHeatingCooling","ZoneAirWaterHeatPumpDetailedElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","ZoneBoilerDetailedBiomassHeatingDHWStandard","ZoneAirWaterHeatPumpGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingTurbine","ZoneAirWaterHeatPumpDetailedGasHeatingDHW","ZoneBoilerDetailedOilHeatingDHWCondensing","ZoneAirAirHeatPumpElectricityHeating","ZoneInstantaneousBoilerDetailedGasDHWCondensing","ZoneAirWaterHeatPumpDetailedGasHeating","ZoneElectricHeaterWaterElectricityDHW","ZoneAirWaterHeatPumpGasDHW","ZoneInletOutletIntakeFlowVentilation","ZoneCoolingDehumidifyingDemand","ZoneCombinedHeatPowerDetailedGasHeatingTurbine","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityCoolingSourceUser","ZoneWaterWaterHeatPumpGasHeatingDryTower","ZoneCombinedHeatPowerGasHeatingDHWFuelCell","ZoneWaterWaterHeatPumpElectricityCoolingHumidTower","ZoneDoubleFlowVentilationWithRecovery","ZoneWaterWaterHeatPumpGasCoolingDryTower","ZoneAirAirHeatPumpDetailedElectricityHeatingCooling","ZoneAirAirHeatPumpDetailedElectricityHeating","ZoneWaterWaterHeatPumpDetailedElectricityCoolingDryTower","ZoneAirWaterHeatPumpElectricityHeating","ZoneWaterWaterHeatPumpElectricityCoolingDryTower","ZoneAirAirHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCoolingDehumidifying","ZoneAirWaterHeatPumpDetailedGasDHW","ZoneBoilerGasDHWStandard","ZoneInstantaneousBoilerDetailedGasDHWStandard","ZoneWaterWaterHeatPumpDetailedGasCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityHeatingCooling","ZoneSingleFlowVentilation","ZoneDHWDemand","ZoneCombinedHeatPowerGasHeatingFuelCell","ZoneCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","ZoneInstantaneousBoilerElectricityHeatingStandard","ZoneBoilerOilHeatingStandard","ZoneWaterWaterHeatPumpGasHeatingCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityDHW","ZoneAirAirHeatPumpDetailedElectricityCooling","ZoneWaterWaterHeatPumpGasHeatingSourceUser","ZoneAirWaterHeatPumpGasCooling","ZoneAirWaterHeatPumpElectricityDHW","ZoneVentHeatingElementVentilation","ZoneBoilerBiomassHeatingStandard","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCooling","ZoneBoilerGasHeatingStandard","ZoneBoilerOilDHWCondensing","ZoneElectricHeaterWaterElectricityDHWSolar","ZoneBoilerDetailedGasHeatingDHWCondensing","ZoneWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","ZoneBoilerDetailedOilHeatingStandard","ZoneAirAirHeatPumpElectricityHeatingCooling","ZoneElectricHeaterElectricityHeating","ZoneAirWaterHeatPumpGasHeating","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCooling","ZoneAirHandlingUnitReturnAirBoilerDetailedStandardGasHeating","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCooling","ZoneInstantaneousBoilerGasDHWStandard","ZoneBoilerBiomassHeating","ZoneBoilerGasDHWCondensing","ZoneBoilerOilHeatingCondensing","ZoneInstantaneousBoilerElectricityDHWStandard","ZoneAirAirHeatPumpDetailedElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpDetailedElectricityCoolingDehumidifying","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeating","ZoneCombinedHeatPowerGasHeatingInternalCombustionEngine","ZoneBoilerDetailedGasHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingCoolingDryTower","ZoneHeatRecoveryVentilation","ZoneBoilerOilDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","ZoneWaterWaterHeatPumpElectricityHeatingDryTower","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDryTower","ZoneBoilerDetailedGasDHWStandard","ZoneAirWaterHeatPumpDetailedElectricityHeating","ZoneAirWaterHeatPumpElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","ZoneWaterWaterHeatPumpGasHeatingDHWSourceUser","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeating","ZoneAirWaterHeatPumpDetailedGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingStirling","ZoneWaterWaterHeatPumpGasCoolingHumidTower","ZoneBoilerBiomassHeatingCondensing","ZoneAirAirHeatPumpElectricityCooling","BuildingWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","BuildingSubstationHxHeatingMT","BuildingWaterWaterHeatPumpElectricityHeatingDHWSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","BuildingBoilerDetailedGasHeatingCondensing","BuildingBoilerBiomassHeatingCondensing","BuildingAirWaterHeatPumpElectricityDHW","BuildingBoilerDetailedGasHeatingDHWStandard","BuildingAirWaterHeatPumpDetailedElectricityHeatingCooling","BuildingWaterWaterHeatPumpElectricityHeatingSourceUser","BuildingBoilerDetailedBiomassHeatingDHWStandard","BuildingBoilerOilHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingDryTower","BuildingBoilerOilHeatingCondensing","BuildingBoilerDetailedGasHeatingDHWCondensing","BuildingBoilerDetailedBiomassHeatingCondensing","BuildingSubstationHeatPumpDetailedCooling","BuildingAirWaterHeatPumpGasHeatingCooling","BuildingBoilerDetailedOilHeatingDHWStandard","BuildingSubstationHxCooling","BuildingSubstationThermoFrigoPumpHeatingDHW","BuildingCombinedHeatPowerDetailedGasHeatingTurbine","BuildingCombinedHeatPowerGasHeatingDHWStirling","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCoolingDHW","BuildingCombinedHeatPowerDetailedGasHeatingDHWStirling","BuildingBoilerDetailedOilHeatingCondensing","BuildingSubstationHxDHW","BuildingBoilerDetailedGasHeatingStandard","BuildingSubstationHeatPumpHeating","BuildingAirWaterHeatPumpDetailedElectricityHeatingDHW","BuildingWaterWaterHeatPumpDetailedElectricityCoolingDryTower","BuildingBoilerDetailedBiomassHeatingStandard","BuildingBoilerGasHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","BuildingSubstationSimpleThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingDHWHT","BuildingWaterWaterHeatPumpDetailedGasCoolingHumidTower","BuildingBoilerGasHeatingDHWCondensing","BuildingAirWaterHeatPumpGasHeatingDHW","BuildingCustomHeatPumpElectricityDHW","BuildingAirWaterHeatPumpDetailedElectricityCooling","BuildingCombinedHeatPowerGasHeatingDHWInternalCombustionEngine","BuildingSubstationHeatPumpDetailedHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","BuildingSubstationHeatPumpHeatingDHW","BuildingAirWaterHeatPumpDetailedGasHeating","BuildingSubstationHeatPumpDHW","BuildingWaterWaterHeatPumpElectricityHeatingCoolingDryTower","BuildingSubstationHxCoolingLT","BuildingSubstationSimpleThermoFrigoPumpHeatingCoolingDHW","BuildingAirWaterHeatPumpDetailedElectricityDHW","BuildingAirWaterHeatPumpGasHeating","BuildingCombinedHeatPowerGasHeatingTurbine","BuildingWaterWaterHeatPumpGasHeatingDHWSourceUser","BuildingSubstationHeatPumpCooling","BuildingAirWaterHeatPumpDetailedGasHeatingDHW","BuildingSubstationHxHeatingHT","BuildingCombinedHeatPowerGasHeatingDHWFuelCell","BuildingWaterWaterHeatPumpDetailedGasCoolingDryTower","BuildingBoilerDetailedBiomassHeatingDHWCondensing","BuildingWaterWaterHeatPumpGasCoolingDryTower","BuildingBoilerGasHeatingDHWStandard","BuildingBoilerGasDHWStandard","BuildingWaterWaterHeatPumpGasCoolingHumidTower","BuildingAirWaterHeatPumpElectricityHeatingDHW","BuildingBoilerBiomassHeatingDHWStandard","BuildingBoilerOilHeatingDHWCondensing","BuildingSubstationHxHeatingDHW","BuildingWaterWaterHeatPumpElectricityCoolingSourceUser","BuildingSubstationHxCoolingHT","BuildingCombinedHeatPowerGasHeatingFuelCell","BuildingSubstationHxHeating","BuildingCombinedHeatPowerDetailedGasHeatingDHWTurbine","BuildingCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","BuildingBoilerDetailedGasDHWCondensing","BuildingAirWaterHeatPumpElectricityHeatingCooling","BuildingCustomHeatPumpElectricityHeating","BuildingSubstationHeatPumpDetailedDHW","BuildingAirWaterHeatPumpDetailedElectricityHeating","BuildingBoilerDetailedOilHeatingDHWCondensing","BuildingBoilerOilHeatingDHWStandard","BuildingSubstationThermoFrigoPumpCooling","BuildingSubstationHxHeatingCooling","BuildingSubstationHeatPumpDetailedHeating","BuildingSubstationHeatPumpDetailedHeatingDHW","BuildingCustomHeatPumpElectricityHeatingDHW","BuildingBoilerGasHeatingCondensing","BuildingSubstationHeatPumpHeatingCooling","BuildingSubstationThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingLT","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","BuildingWaterWaterHeatPumpElectricityCoolingHumidTower","BuildingSubstationThermoFrigoPumpHeating","BuildingSubstationHxCoolingMT","BuildingCombinedHeatPowerGasHeatingStirling","BuildingWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","BuildingAirWaterHeatPumpDetailedGasCooling","BuildingBoilerDetailedGasDHWStandard","BuildingBoilerBiomassHeatingStandard","BuildingSubstationHxHeatingDHWMT","BuildingSubstationThermoFrigoPumpHeatingCoolingDHW","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCooling","BuildingBoilerBiomassHeatingDHWCondensing","BuildingAirWaterHeatPumpElectricityHeating","BuildingAirWaterHeatPumpDetailedGasHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingStirling","BuildingCombinedHeatPowerGasHeatingInternalCombustionEngine","BuildingWaterWaterHeatPumpElectricityCoolingDryTower","BuildingBoilerDetailedOilHeatingStandard","BuildingAirWaterHeatPumpDetailedGasDHW","BuildingCombinedHeatPowerGasHeatingDHWTurbine","BuildingWaterWaterHeatPumpGasHeatingDryTower","BuildingWaterWaterHeatPumpGasHeatingCoolingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDryTower"],"Type":"Categorical data","missing value":null},"systems_3":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Systems of the thermal zone","Name in dimosim":"systems","Name in geoJSON":"systems_3","Possible Values":["DistrictDistributedwaterstorage","DistrictBoilerBiomassHeatingDHWCondensing","DistrictCustomGenerator","DistrictWaterWaterHeatPumpDryCoolingTowerCooling","DistrictWaterWaterHeatPumpDetailedDryTowerHeatingDHW","DistrictTemperedSourceUserPowerHeatingCooling","DistrictGeothermal","DistrictMultiGeneratorTemperedSourcePower","DistrictMultiGeneratorTemperedSource","DistrictWaterWaterHeatPumpHumidCoolingTowerCooling","DistrictWaterWaterHeatPumpDryTowerHeatingCooling","DistrictTemperedSourceUserHxHeatingCooling","DistrictMultiGeneratorTemperedSourceHx","DistrictWaterWaterHeatPumpDryTowerHeatingDHW","DistrictThermoRefrigeratingHeatPumpSourceUserHeatingCooling","DistrictMultigeneratorCooling","DistrictMultigeneratorHeating","DistrictBoilerGasHeatingDHWCondensing","DistrictWaterWaterHeatPumpSourceUserHeatingCooling","ZoneBoilerDetailedOilHeatingCondensing","ZoneCoolingDemand","ZoneWaterWaterHeatPumpDetailedGasHeatingDryTower","ZoneBoilerDetailedBiomassHeatingStandard","ZoneWaterWaterHeatPumpElectricityHeatingDHWSourceUser","ZoneAirWaterHeatPumpDetailedElectricityCooling","ZoneBoilerGasHeatingCondensing","ZoneBoilerDetailedOilHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingSourceUser","ZoneBoilerBiomassDHWCondensing","ZoneBoilerDetailedGasHeatingCondensing","ZoneCombinedHeatPowerDetailedGasHeatingDHWStirling","ZoneBoilerBiomassDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingStirling","ZoneBoilerDetailedBiomassHeatingCondensing","ZoneAirWaterHeatPumpDetailedGasCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","ZoneGasHeaterDetailedGasHeating","ZoneWaterWaterHeatPumpDetailedGasCoolingHumidTower","ZoneDoubleFlowVentilationWithoutRecovery","ZoneBoilerDetailedGasHeatingStandard","ZoneCombinedHeatPowerDetailedGasHeatingDHWTurbine","ZoneBoilerDetailedGasDHWCondensing","ZoneBoilerDetailedBiomassHeatingDHWCondensing","ZoneAirWaterHeatPumpElectricityCooling","ZoneHeatingDemand","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","ZoneBoilerOilHeating","ZoneAirWaterHeatPumpElectricityHeatingCooling","ZoneAirWaterHeatPumpDetailedElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","ZoneBoilerDetailedBiomassHeatingDHWStandard","ZoneAirWaterHeatPumpGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingTurbine","ZoneAirWaterHeatPumpDetailedGasHeatingDHW","ZoneBoilerDetailedOilHeatingDHWCondensing","ZoneAirAirHeatPumpElectricityHeating","ZoneInstantaneousBoilerDetailedGasDHWCondensing","ZoneAirWaterHeatPumpDetailedGasHeating","ZoneElectricHeaterWaterElectricityDHW","ZoneAirWaterHeatPumpGasDHW","ZoneInletOutletIntakeFlowVentilation","ZoneCoolingDehumidifyingDemand","ZoneCombinedHeatPowerDetailedGasHeatingTurbine","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpElectricityCoolingDehumidifying","ZoneWaterWaterHeatPumpElectricityCoolingSourceUser","ZoneWaterWaterHeatPumpGasHeatingDryTower","ZoneCombinedHeatPowerGasHeatingDHWFuelCell","ZoneWaterWaterHeatPumpElectricityCoolingHumidTower","ZoneDoubleFlowVentilationWithRecovery","ZoneWaterWaterHeatPumpGasCoolingDryTower","ZoneAirAirHeatPumpDetailedElectricityHeatingCooling","ZoneAirAirHeatPumpDetailedElectricityHeating","ZoneWaterWaterHeatPumpDetailedElectricityCoolingDryTower","ZoneAirWaterHeatPumpElectricityHeating","ZoneWaterWaterHeatPumpElectricityCoolingDryTower","ZoneAirAirHeatPumpElectricityHeatingCoolingDehumidifying","ZoneWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCoolingDehumidifying","ZoneAirWaterHeatPumpDetailedGasDHW","ZoneBoilerGasDHWStandard","ZoneInstantaneousBoilerDetailedGasDHWStandard","ZoneWaterWaterHeatPumpDetailedGasCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityHeatingCooling","ZoneSingleFlowVentilation","ZoneDHWDemand","ZoneCombinedHeatPowerGasHeatingFuelCell","ZoneCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","ZoneInstantaneousBoilerElectricityHeatingStandard","ZoneBoilerOilHeatingStandard","ZoneWaterWaterHeatPumpGasHeatingCoolingDryTower","ZoneAirWaterHeatPumpDetailedElectricityDHW","ZoneAirAirHeatPumpDetailedElectricityCooling","ZoneWaterWaterHeatPumpGasHeatingSourceUser","ZoneAirWaterHeatPumpGasCooling","ZoneAirWaterHeatPumpElectricityDHW","ZoneVentHeatingElementVentilation","ZoneBoilerBiomassHeatingStandard","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityCooling","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityCooling","ZoneBoilerGasHeatingStandard","ZoneBoilerOilDHWCondensing","ZoneElectricHeaterWaterElectricityDHWSolar","ZoneBoilerDetailedGasHeatingDHWCondensing","ZoneWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","ZoneBoilerDetailedOilHeatingStandard","ZoneAirAirHeatPumpElectricityHeatingCooling","ZoneElectricHeaterElectricityHeating","ZoneAirWaterHeatPumpGasHeating","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeatingCooling","ZoneAirHandlingUnitReturnAirBoilerDetailedStandardGasHeating","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeatingCooling","ZoneInstantaneousBoilerGasDHWStandard","ZoneBoilerBiomassHeating","ZoneBoilerGasDHWCondensing","ZoneBoilerOilHeatingCondensing","ZoneInstantaneousBoilerElectricityDHWStandard","ZoneAirAirHeatPumpDetailedElectricityHeatingCoolingDehumidifying","ZoneAirAirHeatPumpDetailedElectricityCoolingDehumidifying","ZoneAirHandlingUnitReturnAirWaterWaterHeatPumpElectricityHeating","ZoneCombinedHeatPowerGasHeatingInternalCombustionEngine","ZoneBoilerDetailedGasHeatingDHWStandard","ZoneWaterWaterHeatPumpElectricityHeatingCoolingDryTower","ZoneHeatRecoveryVentilation","ZoneBoilerOilDHWStandard","ZoneCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","ZoneWaterWaterHeatPumpElectricityHeatingDryTower","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDryTower","ZoneBoilerDetailedGasDHWStandard","ZoneAirWaterHeatPumpDetailedElectricityHeating","ZoneAirWaterHeatPumpElectricityHeatingDHW","ZoneWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","ZoneWaterWaterHeatPumpGasHeatingDHWSourceUser","ZoneAirHandlingUnitReturnAirAirWaterHeatPumpElectricityHeating","ZoneAirWaterHeatPumpDetailedGasHeatingCooling","ZoneCombinedHeatPowerGasHeatingStirling","ZoneWaterWaterHeatPumpGasCoolingHumidTower","ZoneBoilerBiomassHeatingCondensing","ZoneAirAirHeatPumpElectricityCooling","BuildingWaterWaterHeatPumpDetailedGasHeatingDHWDryTower","BuildingSubstationHxHeatingMT","BuildingWaterWaterHeatPumpElectricityHeatingDHWSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingCoolingDryTower","BuildingBoilerDetailedGasHeatingCondensing","BuildingBoilerBiomassHeatingCondensing","BuildingAirWaterHeatPumpElectricityDHW","BuildingBoilerDetailedGasHeatingDHWStandard","BuildingAirWaterHeatPumpDetailedElectricityHeatingCooling","BuildingWaterWaterHeatPumpElectricityHeatingSourceUser","BuildingBoilerDetailedBiomassHeatingDHWStandard","BuildingBoilerOilHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingDryTower","BuildingBoilerOilHeatingCondensing","BuildingBoilerDetailedGasHeatingDHWCondensing","BuildingBoilerDetailedBiomassHeatingCondensing","BuildingSubstationHeatPumpDetailedCooling","BuildingAirWaterHeatPumpGasHeatingCooling","BuildingBoilerDetailedOilHeatingDHWStandard","BuildingSubstationHxCooling","BuildingSubstationThermoFrigoPumpHeatingDHW","BuildingCombinedHeatPowerDetailedGasHeatingTurbine","BuildingCombinedHeatPowerGasHeatingDHWStirling","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCoolingDHW","BuildingCombinedHeatPowerDetailedGasHeatingDHWStirling","BuildingBoilerDetailedOilHeatingCondensing","BuildingSubstationHxDHW","BuildingBoilerDetailedGasHeatingStandard","BuildingSubstationHeatPumpHeating","BuildingAirWaterHeatPumpDetailedElectricityHeatingDHW","BuildingWaterWaterHeatPumpDetailedElectricityCoolingDryTower","BuildingBoilerDetailedBiomassHeatingStandard","BuildingBoilerGasHeatingStandard","BuildingWaterWaterHeatPumpElectricityHeatingCoolingSourceUser","BuildingWaterWaterHeatPumpDetailedGasHeatingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingCoolingDryTower","BuildingSubstationSimpleThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingDHWHT","BuildingWaterWaterHeatPumpDetailedGasCoolingHumidTower","BuildingBoilerGasHeatingDHWCondensing","BuildingAirWaterHeatPumpGasHeatingDHW","BuildingCustomHeatPumpElectricityDHW","BuildingAirWaterHeatPumpDetailedElectricityCooling","BuildingCombinedHeatPowerGasHeatingDHWInternalCombustionEngine","BuildingSubstationHeatPumpDetailedHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingInternalCombustionEngine","BuildingSubstationHeatPumpHeatingDHW","BuildingAirWaterHeatPumpDetailedGasHeating","BuildingSubstationHeatPumpDHW","BuildingWaterWaterHeatPumpElectricityHeatingCoolingDryTower","BuildingSubstationHxCoolingLT","BuildingSubstationSimpleThermoFrigoPumpHeatingCoolingDHW","BuildingAirWaterHeatPumpDetailedElectricityDHW","BuildingAirWaterHeatPumpGasHeating","BuildingCombinedHeatPowerGasHeatingTurbine","BuildingWaterWaterHeatPumpGasHeatingDHWSourceUser","BuildingSubstationHeatPumpCooling","BuildingAirWaterHeatPumpDetailedGasHeatingDHW","BuildingSubstationHxHeatingHT","BuildingCombinedHeatPowerGasHeatingDHWFuelCell","BuildingWaterWaterHeatPumpDetailedGasCoolingDryTower","BuildingBoilerDetailedBiomassHeatingDHWCondensing","BuildingWaterWaterHeatPumpGasCoolingDryTower","BuildingBoilerGasHeatingDHWStandard","BuildingBoilerGasDHWStandard","BuildingWaterWaterHeatPumpGasCoolingHumidTower","BuildingAirWaterHeatPumpElectricityHeatingDHW","BuildingBoilerBiomassHeatingDHWStandard","BuildingBoilerOilHeatingDHWCondensing","BuildingSubstationHxHeatingDHW","BuildingWaterWaterHeatPumpElectricityCoolingSourceUser","BuildingSubstationHxCoolingHT","BuildingCombinedHeatPowerGasHeatingFuelCell","BuildingSubstationHxHeating","BuildingCombinedHeatPowerDetailedGasHeatingDHWTurbine","BuildingCombinedHeatPowerDetailedGasHeatingDHWInternalCombustionEngine","BuildingBoilerDetailedGasDHWCondensing","BuildingAirWaterHeatPumpElectricityHeatingCooling","BuildingCustomHeatPumpElectricityHeating","BuildingSubstationHeatPumpDetailedDHW","BuildingAirWaterHeatPumpDetailedElectricityHeating","BuildingBoilerDetailedOilHeatingDHWCondensing","BuildingBoilerOilHeatingDHWStandard","BuildingSubstationThermoFrigoPumpCooling","BuildingSubstationHxHeatingCooling","BuildingSubstationHeatPumpDetailedHeating","BuildingSubstationHeatPumpDetailedHeatingDHW","BuildingCustomHeatPumpElectricityHeatingDHW","BuildingBoilerGasHeatingCondensing","BuildingSubstationHeatPumpHeatingCooling","BuildingSubstationThermoFrigoPumpHeatingCooling","BuildingSubstationHxHeatingLT","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDHWDryTower","BuildingWaterWaterHeatPumpElectricityCoolingHumidTower","BuildingSubstationThermoFrigoPumpHeating","BuildingSubstationHxCoolingMT","BuildingCombinedHeatPowerGasHeatingStirling","BuildingWaterWaterHeatPumpDetailedElectricityCoolingHumidTower","BuildingAirWaterHeatPumpDetailedGasCooling","BuildingBoilerDetailedGasDHWStandard","BuildingBoilerBiomassHeatingStandard","BuildingSubstationHxHeatingDHWMT","BuildingSubstationThermoFrigoPumpHeatingCoolingDHW","BuildingSubstationSimpleThermoFrigoPumpDetailedHeatingCooling","BuildingBoilerBiomassHeatingDHWCondensing","BuildingAirWaterHeatPumpElectricityHeating","BuildingAirWaterHeatPumpDetailedGasHeatingCooling","BuildingCombinedHeatPowerDetailedGasHeatingStirling","BuildingCombinedHeatPowerGasHeatingInternalCombustionEngine","BuildingWaterWaterHeatPumpElectricityCoolingDryTower","BuildingBoilerDetailedOilHeatingStandard","BuildingAirWaterHeatPumpDetailedGasDHW","BuildingCombinedHeatPowerGasHeatingDHWTurbine","BuildingWaterWaterHeatPumpGasHeatingDryTower","BuildingWaterWaterHeatPumpGasHeatingCoolingDryTower","BuildingWaterWaterHeatPumpDetailedElectricityHeatingDryTower"],"Type":"Categorical data","missing value":null},"usage_lighting":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Usage lighting type of thermal zone","Name in dimosim":"usage_lighting","Name in geoJSON":"usage_lighting","Possible Values":"None or str","Type":"Categorical data"},"usage_zone_type":{"Applied to class":"ThermalZone","Default":null,"Full Name":"Usage type of thermal zone","Name in dimosim":"usage_zone_type","Name in geoJSON":"usage_zone_type","Possible Values":["housing","office","shop","primary_school","hotel","public_facilities","centre_sport","student_residence","powerdis_housing",null,"dwelling"],"Type":"Categorical data"}}